CNC数控系统通讯参数设置

电场很强的维修电工 106

前言:

现在大家对“1111加5121等于几”都比较着重,小伙伴们都想要分析一些“1111加5121等于几”的相关资讯。那么小编也在网络上收集了一些对于“1111加5121等于几””的相关文章,希望大家能喜欢,姐妹们一起来学习一下吧!

CNC数控系统通讯参数设置

来源:

AllenBradley(美国:AB)

AllenBradley 8600

Parameter

Value

Comments

Baud Rate

2400

Parity

E

Databits

7

Stop Bits

2

Acramatic(美国:辛辛那提·米拉克龙)

Acramatic 850 (SX)

Parameter

Value

Comments

Baud Rate

2400

Also set these values in the DNC software

Parity

N

Databits

8

Stop Bits

1

Drip Feed ?

We do not believe drip feed is possible with this controller

See bottom of this page for Cable diagrams

Anilam(美国:艾科瑞)

Anilam Crusader

Parameter

Value

Comments

Group 1

AUX 2767

7 Data bits

Group 2

AUX 2772

Even Parity

Group 3

AUX 2784

Baud Rate 1200

Group 4

AUX 2790

No Flow Control

Group 5

AUX 2700

Send from Crusader to PC

Group 6

AUX 2701

Receive data in Crusdare (From PC)

Bosch(美国:博世·力士乐)

Bosch CC220 and CC320

Parameter

Value

Comments

Device

Port

(V240,1)

DCR

9600

Baud Rate

Status

SW Control

DFS

RECOGNISE WITH LEADER WITH TRAILER

Time Out

10 SEC

Haas(美国:哈斯)

Haas

Parameter

Value

Comments

11

9600

12

Even

13

1

14

Xon/Xoff

37

7

24

None

25

CR,LF

41

On

50

Xon/Xoff

54

9600

69

Off

70

On

Boss

Bridgeport Boss

Parameter

Value

Comments

Baud Rate

4800

Parity

Even

Databits

7

Stop Bits

1

USE DNC Port B

See Cable diagrams below

DeltaDynaPath(美国: )

Delta Dynapath

Parameter

Value

Comments

Baud Rate

Any

Suggest 2400 but not higher than 9600)

Databits

7

Parity

Even

Stop bits

1

FadalCNC(美国:法道)

Fadal 88

Parameter

Value

Comments

Baud Rate

9600

Suggest 2400 but not higher than 9600)

Databits

7

Parity

Even

Stop bits

1

Fanuc(日本:发那科)

Fanuc i(M/T)

Parameter

Value

Comments

0000

0000 0010

0020

0

0100

0010 1000

0101

1000 1001

0102

0

0103

11

9 = 2400,10 = 4800,11 = 9600* (recommended)

0138

1000 0000

TV Check

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

Punch Code

1

1 = ISO (0=EIA Never use EIA)

I/O Channel

0

PWE

1

Drip Feed ?

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 0(M/T)

Parameter

Value

Comments

0002

1000 0001

0038

0100 0000

0552

11

9 = 2400,10 = 4800,11 = 9600* (recommended)

TV On/Off

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

ISO

1

1 = ISO (0=EIA Never use EIA)

I/O

0

PWE

1

TAPEF

0

Drip Feed ?

To drip feed enable para G127.5

使G127.5 DNC操作信号动作。

Select Auto (DNC) mode on the control - Press Cycle Start.

选择自动(DNC)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Fanuc 3(M/T)

Parameter

Value

Comments

0005

0000 0001

0068

10

9 = 2400,10 = 4800* (recommended),11 = 9600

TV On/Off

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

ISO

1

1 = ISO (0=EIA Never use EIA)

I/O

0

Fanuc 6,9(M/T) ,0P

Parameter

Value

Comments

340

2

341

2

311

0011 1010

Baud rate - see table below for valid options.

0011 1000 = 2400

0011 1001 = 4800

0011 1010 = 9600 * (recommended)

TV Check

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

Punch Code

1

1 = ISO (0=EIA Never use EIA)

Input Unit

0

Input Device 1

1

Input Device 2

1

Fanuc 10,11,12,15 (M/T)

Parameter

Value

Comments

0000

****1010

0011

******00

0020

1

0021

1

2201

******00

5001

1

5002

2

5003

3

5110

4

5111

2

5112

10

* Baud rate - see table below for valid options.

5120

4

5121

2

5122

10

* Baud rate - see table below for valid options.

5130

4

5131

2

5132

10

* Baud rate - see table below for valid options.

9 = 2400

10 = 4800 * (recommended)

11 = 9600

TV Check

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

ISO

0

0 = ISO (1=EIA Never use EIA)

Input Device

1

Output Device

1

Drip Feed ?

Select Tape mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Note: Not all fanuc of this type can drip feed - must be enabled in the control.

Fanuc 16,18,21 (M/T)

Parameter

Value

Comments

0000

0000 0010

0020

0

0100

0010 1000

0101

1000 1001

0102

0

0103

10

9 = 2400,10 = 4800* (recommended),11 = 9600

TV Check

0

0 = TV Check OFF (1= TV Check ON - Never enable TV Check)

Punch Code

1

1 = ISO (0=EIA Never use EIA)

I/O Channel

0

Tape Format

0

Drip Feed ?

Select TAPE mode on the control - Press Cycle Start.

选择TAPE(磁带)控制状态,按(循环启动)。

Then go to the computer, prepare the program and click 'Send'. When data begins to flow the machine will start moving.

然后去电脑,准备程序,点击“发送”,当数据开始传送时,机床就会开始移动。

Mazak(日本:马扎克)

Mazak M Plus / T Plus

Parameter

Value

Comments

User Parameter #5

G1

1

= Baud Rate 9600

G2

3

= 2 Stop Bits

G3

0

= Even Parity

G5

3

= 8 Data Bits (Set DNC to software to 7 Databits)

G6

1

G10

3

Use xOn/xOff flow control (DC1 and DC3)

G12

0

Do not use DC2 and DC4)

G13

50

G17

0000 0000

G31

0000 0000

G33

50

G34

10

G39

0000 0100

G40

0000 0000

G48

0

Note : Even though the Mazak is set to 8 Databits - ensure than the DNC software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak M32

Parameter

Value

Comments

G19

2

2 = 4800 3 = 2400

G20

3

= 2 Stop Bits

G22

0

= Even Parity

G23

3

= 8 Data Bits (Set DNC to software to 7 Databits)

G24

1

G25

0

G26

0

G27

0

Use ISO code

G28

0

G29

3

Note : Even though the Mazak is set to 8 Databits - ensure than the DNC software is set to 7 databits.

In the DNC software select xOn/xOff flow control

Mazak T32 - M2

Parameter

Value

Comments

I 1

2

I 2

3

I 3

0

I 4

0

I 5

3

I 6

3

I 7

1

I 8

5

I 9

0

I 10

1

I 11

1

I 12

0

I 13

0

I 14

0

I 15

30

I 16

0

I 24

0

I 58

0000 0000

Note : Even though the Mazak may be set to 8 Databits No Parity - ensure that the DNC software is set to 7 databits with Even Parity.

Mazak T2

Parameter

Value

Comments

A15

206

A16

1

= No Parity ( But in the DNC software select Even Parity )

A17

6

= Baud rate 4800

A18

6

A19

0

A20

1

Use ISO

A21

1

A22

10

A23

10

A24

0

TV Check Off

A30

3

A31

109

A32

70

Note : Even though the Mazak is set to 8 Databits No Parity - ensure that the DNC software is set to 7 databits with Even Parity.

Mitsubishi(日本:三菱)

Mitsubishi 300-500

Parameter

Value

Comments

I/O Base parameters

1

1

2

1

3

0

6

0

7

200

I/O Devive parameters

2

2

3

3

4

0

5

1

6

3

7

3

11

3

12

1

Mitsubish M50,60/60s,E60/68,M64/65/66

Parameter

Value

Comments

I/O Base parameters

9001

2

Input Port

9002

1

Input Device

9003

2

Out Port

9004

0

Out device

9005

2

Tape Mode

I/O Devive parameters

9101

Out/In

9201

Out/In

9102

2

Baud rate 4800

9202

2

9103

1

1 Stop Bit

9203

1

9104

1

Use Parity = Yes

9204

1

9105

1

Parity = Even

9205

1

9106

2

7 Databits

9206

2

9108

3

Use xOnx/Off (DC1 and DC3)

9208

3

9109

1

9209

1

Okuma(日本:大隈)

Okuma 5000 / 7000

Parameter

Value

Comments

1

0

number of spaces/ bytes of tape leader

34

10

39

4800

Baud Rate

44

0

45

0

46

0

54

1

57

90

0000 1011

Optional parameter bits #1 (ISO Code)

1010 1010

Okuma 7000 Opt Para #8

1010 0010

Optional parameter bits #12 (Stop Bits/Parity)

Function

Punch

Go to the 'Edit mode' [F3] (PIP), [F2] (Punch), type file name, then [Return]

Read

Go to the 'Edit mode' [F3] (PIP), [F1] (Read), [Return]

Yasnac(日本:安川)

Yasnac LX MX

Parameter

Value

Comments

6000

1xxx xxxx

x = don't change

6001

1xxx xxxx

(Maybe only required on MX-2)

6003

xxx1 xxx1

6021

x111 xx1x

(Maybe only required on LX/MX-1)

6022

xxxx xx11

6026 / 6028

0001 1000

Baud rate - 2400

7 Data bits,Parity Even,2 Stop bits

Amada(日本:天田)

Amada

Parameter

Value

Comments

Baud Rate

2400

Also set these values in the DNC software

Parity

Even

Databits

7

Stop Bits

2

Punch Code

1

1=ISO (Do not use 0 EIA)

Dec Inp

0

See cable diagrams below

Heidenhain(德国:海德汉)

Heidenhain TNC 145

Parameter

Value

Comments

Baud rate

2400

Parity

Even

Databits

7

Stop Bits

2

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For example with easyDnc 4.0 this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 150

Parameter

Value

Comments

MP92

1

Select Multi Func.

MP71

3

BaudRate

2400

(Same as in the DNC software )

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For example with easyDnc 4.7 this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 155,355

Parameter

Value

Comments

MP232

0

MP71

515

MP222

104

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2 StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For example with easyDnc 4.0 this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 415,425

Parameter

Value

Comments

Device

EXT 2

MP 5200.1

2

MP 5201.1

3

MP 5020.1

104

MP 5030.1

0

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2 StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For example with easyDnc 4.0 this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Heidenhain TNC 2500

Parameter

Value

Comments

MP 5020

100

MP 5030

0

in the DNC software Set Baud rate 2400 -7 DataBits -Even -2 StopBits

In the DNC software select RTS/CTS flow control

DNC Software should insert STX and ETX codes into the transmit data - For example with easyDnc 4.0 this is acheived in the DNC Setup window by selecting 'Advanced' and select these options from the drop-lists.

ASCII Start Code = STX (02)

ASCII End Code = ETX (03)

Hinumerik(德国:)

Hinumerik 2000,2100 (M/T)

Parameter

Value

Comments

5010

0

5012

0

5011

1100 0101

= 2400 For other Baud Rates see the table below

5013

1100 0101

Same as 5011 - For other Baud Rates see the table below

1100 0101 = 2400,1100 0110 = 4800

5016

xx10 xxxx

x = do not change

RTS

Line 1

In the DNC software select RTS/CTS flow control

Hinumerik 3000 ,3100 (M/T)

Parameter

Value

Comments

411

1110 1101

= 2400 For other Baud Rates see the table below

412

1110 1101

Same as 5011 - For other Baud Rates see the table below

1110 1101 = 2400,1110 1110 = 4800

416

1xxx xxx1

x = do not change

In the DNC software select RTS/CTS flow control

Sinumerik(德国:西门子)

Sinumerik 3M and 3T

Parameter

Value

Comments

411

1110 1101

= Baud Rate 2400

412

1110 1101

See below for other baud rates

1110 1101 = 2400,1110 1110 = 4800

416

1xxxxxx1

x = Do not change

Sinumerik 8M and 8T

Parameter

Value

Comments

428

1110 1101

= Baud Rate 2400

429

1110 1101

See below for other baud rates

1110 1101 = 2400,1110 1110 = 4800

425

xxxx x0xx

x = Do not change

430

0000 0000

461

xx0x xxxx

x = Do not change

Sinumerik 810and 850 (M/T)

Parameter

Value

Comments

5010

0

5012

0

5011

1111 0101

= Baud Rate 2400

5013

1111 0101

See below for other baud rates

1111 0101 = 2400,1111 0110 = 4800

RTS Line

1

Sinumerik 840D

Parameter

Value

Comments

Serial

1

Device

Standard/WS800A

Device Type

Universal

Protocol

RTS/CTS (Hardware)

Baud rate

9600

Stop bits 2

2

Parity

Even

Bit/character

7

Xon character

11

Xoff character

13

EOT

03

Leader

No

Ready

No

EOB

CRLF

Time out in Sec.

60

Format

Punch tape format

Traub(德国:特劳伯)

Traub TX8

Parameter

Value

Comments

#1

01

0

Parity

04

1

ISO

#2

0

12

5

Baud Rate = 1200

Fagor(西班牙:发格)

Fagor 80xx

Parameter

Value

Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

P001

7

7 Databits

P002

2

Even Parity

P003

2

Stop Bits

After making changes - reset the controller

Fagor 8025T

Parameter

Value

Comments

In the control settings select

9 (Special Modes)

1 (General Parameters)

P000

Valid Baud Rates 2400, 4800 (Same as the DNC Software)

P001

7

7 Databits

P002

2

Even Parity

P003

2

Stop Bits

P605

0001 0000

DNC activate

After making changes - reset the controller

传输故障的解决

1. 检查 PC和 CNC 的端口参数设置是否一致,波特率速度设置不宜太快(太快可能会 丢失数据),也不宜太慢(速度慢当然效率就低了) ;

2. 连接电缆是否有断线,接触不良,焊接是否正确;

3. 通讯软件选择不对,有一些系统必须用原厂的通讯软件;

4. 传输的文件格式不正确;

5. 有较大干扰,选择优质屏蔽电缆做传输线;

6. 如果上述都正确,那就是端口损坏。

另外,曾经使用过数据传送,参数设置也正确的情况下,同样也会发生传送故障,这时把PC的FIFO缓冲区取消或者使“接收缓冲区”与“传输缓冲区”为最低即可。

置方法如下:

打开PC“控制面板”—“系统”—“硬件”—“设备管理器”—“端口”—“通讯端口”,右键,“属性”—“端口设置”—“高级”—“使用FIFO缓存”,使“接收缓冲区”与“传输缓冲区”为最低即可,或者取消“使用FIFO缓存”。